Model | FF-SU10N |
Sensing method | Slot type (Through beam) |
Sensing distance | 10mm(Slot width) |
Sensing object | Opaque: 2×0.8mm min |
Differential Distance | 0.05mm max |
Repeatability Precision | 0.03mm max |
Response time | 1ms max |
Response frequency | 100HZ min |
Light source (wave length) | Infrared LED |
Power supply voltage | DC12~24V±10% ripple (p-p) 5% max |
Current consumption | 10mA max |
Output configuration | NO/NC Selectable |
Indicator | Equipped |
Protection circuits | Power supply reverse polarity protection, Reversed output polarity protection |
Degree of protection | IEC Standard IP65 |
Ambient illumination | On the surface of the receiver, incandescent lamp 3000 lx max, sunlight 3000 lx max. |
Ambient temperature range | Operating: -10~+55℃, Storage: -25~+65℃ |
Ambient humidity range | Operating: 5~85%RH, Storage: 5~95%RH |
Insulation resistance | 20 MΩmin. at 500 VDC |
Voltage resistance | AC1,000V 50/60Hz 1min |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | Destruction: 500m/s², 3 times each in X, Y, and Z directions |
Connection method | Pre-wired Model(2m) |
Material | Case:Polycarbonate; Cable: 0.09mm² 4 corewith rubber insulated cable |
Weight | Approx. 55g |